Chuck
Large standard bolts
Large high-strength bolts
Storage temperature
Ambient temperature for operation
4.1 Battery
Battery operating voltage
Weight, battery
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
5
Preparations at the workplace
WARNING
Risk of injury by inadvertent starting!
▶ Before inserting the battery, make sure that the product is switched off.
▶ Remove the battery before making any adjustments to the power tool or
before changing accessories.
Observe the safety instructions and warnings in this documentation and on
the product.
5.1 Charging the battery
1. Before charging the battery, read the operating instructions for the
charger.
2. Make sure that the contacts on the battery and the contacts on the
charger are clean and dry.
3. Use an approved charger to charge the battery. → page 8
*2343810*
2343810
/
" square drive
1
2
with ball-notch
retention
M8 to M16
M6 to M12
−20 ℃ ... 70 ℃
(−4 ℉ ... 158 ℉)
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
21.6 V
See the end of
these operating
instructions
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
−20 ℃ ... 40 ℃
(−4 ℉ ... 104 ℉)
−10 ℃ ... 45 ℃
(14 ℉ ... 113 ℉)