Télécharger Imprimer la page

Bosch 1506 Consignes De Fonctionnement/Sécurité page 10

Publicité

Les langues disponibles

Les langues disponibles

BM 1609929Y01 05-10:BM 1609929Y01 05-10 5/10/10 9:10 AM Page 10
Service
Preventive maintenance
W RNING
performed by unauthorized
personnel may result in misplacing of
internal wires and components which
could
cause
serious
recommend that all tool service be performed
by a Bosch Factory Service Center or Autho-
rized Bosch Service Station.
TOOL LUBRICATION
Your Bosch tool has been properly lubricated
and is ready to use. It is recommended that
tools with gears be regreased with a special
gear lubricant at every brush change.
CARBON BRUSHES
The brushes and commutator in your tool have
been engineered for many hours of
dependable service. To maintain peak
efficiency of the motor, we recommend every
two to six months the brushes be examined.
Only genuine Bosch replacement brushes
specially designed for your tool should be
used.
BEARINGS
After about 300-400 hours of operation, or at
every second brush change, the bearings
If an extension cord is
W RNING
necessary, a cord with
adequate size conductors that is capable of
carrying the current necessary for your tool
must be used. This will prevent excessive
voltage drop, loss of power or overheating.
Grounded tools must use 3-wire extension
cords that have 3-prong plugs and receptacles.
NOTE: The smaller the gauge number, the heavi-
er the cord.
* Upper and lower blade set 2 607 010 025
* Hex key (5mm)
** Carrying case
All manuals and user guides at all-guides.com
Maintenance
should be replaced at Bosch Factory Service
Center or Authorized Bosch Service Station.
Bearings which become noisy (due to heavy
load or very abrasive material cutting) should
be replaced at once to avoid overheating or
motor failure.
hazard.
We
the power supply before cleaning or
performing any maintenance. The tool may
be cleaned most effectively with compressed
dry air. Always wear safety goggles when
cleaning tools with compressed air.
Ventilation openings and switch levers must be
kept clean and free of foreign matter. Do not
attempt to clean by inserting pointed objects
through openings.
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated cleaning
solvents, ammonia and household detergents
that contain ammonia.
Extension Cords
RECOMMENDED SIZES OF EXTENSION CORDS
Tool's
Ampere
Rating
Accessories
(*= standard equipment)
(**= optional accessories)
-10-
Cleaning
To avoid accidents always
W RNING
disconnect the tool from
Certain cleaning agents
C UTION
and
solvents
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Cord Length in Feet
25
50
100 150
3-6
18
16
16
14
6-8
18
16
14
12
8-10
18
16
14
12
10-12
16
16
14
12
12-16
14
12
damage
2
Wire Sizes in mm
Cord Length in Meters
15
30
60
120
0.75 0.75 1.5
2.5
0.75 1.0 2.5
4.0
0.75 1.0 2.5
4.0
1.0 2.5 4.0

Publicité

loading