3.6.6. Sensor settings
Menu
Sensor
Cover/Ext cmd
Flow/pH Can
Salt
Temperature
Sensor activated
Cover
External command
Flow
Empty container
Salt
Salt level equal to or greater than 2.5 g/L
Temperature
All manuals and user guides at all-guides.com
Setting
Mode
Type
Mode
Type
-
Ext cmd : external command.
pH Can : empty container sensor.
ON : sensor activated.
OFF : sensor disabled.
NO : switch normally open.
NC : switch normally closed.
Configuration
Open cover
Closed cover
Command activated
Command not activated
Sufficient flow
Zero flow
Empty container
Container not empty
Salt level less than 2.5 g/L
(or 1.5 g/L if Low Salt equipment)
(or 1.5 g/L if Low Salt equipment)
Water temperature below 15°C
Water temperature equal to or higher
than 15°C
* Modifiable value on the PRO model.
Possible settings
Cover
OFF
Ext cmd
NO
NC
Flow
OFF
pH Can
NO
NC
ON
OFF
Specific
Production
display
-
Maintained
Divided by 5*
-
Maintained
Stopped
-
Maintained
Stopped
Maintained
-
Maintained
Stopped
-
Maintained
Stopped
-
Maintained
Default setting
Cover
NO
OFF
NO
ON
pH regulation
Maintained
Stopped
Maintained
8