350-41659
Read the complete manual before carrying out the installation and activating the system. Keep the
manual for future reference.
1. DESCRIPTION
This motion detector registers movement via a passive infrared sensor (PIR).
You use this device in combination with a DALI master (350-41657, 350-41650 or 350-41680) to expand the
detection area. A maximum of 20 slaves can be connected to one master. Both the master and the slave have the
same detection range (a circle with a diameter of 8 – 12 m). To cover a complete surface with multiple detectors,
it is recommended to take into account an overlap of around 30 %.
The slave controls the lighting according to the parameters set on the master. For more information, consult
the manual of the master.
The detector has a very flat design of only 5 mm, so that it can be mounted almost flush with the ceiling.
2. INSTALLATION
2.1. Connection
Danger: Do not install the detector while it is connected to the mains voltage supply. Do not connect the device
to the power supply until the installation is completed. It is not necessary to assemble the detector immediately
because it has removable connectors. This allows the connector first to be cabled separately and then to be
pushed back into the detector.
The detector is powered through the DALI bus. Refer to the wiring diagram in fig. 1.
2.2. Mounting
Tip: Do not install the detector in the vicinity of heat sources such as stoves or electric heaters, air currents
(ventilation systems) or moving objects (see fig. 2). This can activate the device unnecessarily because the device
reacts to movement and heat.
The detector is suitable for direct mounting in the ceiling (see fig. 4). As a protection, the detector has a cover around
the connectors. In addition, the detector also has standard spring terminals that allow easy mounting in the ceiling.
Note: It is important to install the slave only after the fittings have been programmed and divided into zones.
Otherwise problems may occur during programming and zone assignment.
3. MAINTENANCE
Dirt may prevent the detector from functioning properly. Therefore, always keep the lens clean and dry. Use a
damp cloth and water with some detergent to clean the lens. Never exert pressure to wipe the lens clean. If the
lens or other parts of the detector are defective, please contact an authorised installer.
4. TECHNICAL DATA
visible dimensions (fig. 5)
invisible dimensions (fig. 5)
power supply
detection range
detection angle
mounting height
ambient temperature
protection degree
protection class
quality mark
5. WARNINGS REGARDING INSTALLATION
• The installation should be carried out by a registered installer and in compliance with the statutory regulations.
• This user manual should be presented to the user. It should be included in the electrical installation file,
and it should be passed on to any new owners. Additional copies are available on the Niko website or via
the Niko support service.
• During installation, the following should be taken into account (non-exhaustive list):
- the statutory laws, standards and regulations.
- the technology currently available at the time of installation.
- this user manual, which only states general regulations and should therefore be read within the scope
of each specific installation.
- the rules of proper workmanship.
This product complies with all of the relevant European guidelines and regulations. If applicable, you can find the
EC declaration of conformity regarding this product at www.niko.eu.
6. NIKO SUPPORT
In case of doubt or for the specific exchange procedure in case of a possible defect, contact the Niko support
service in Belgium at +32 3 778 90 80 or your wholesaler/installer. Contact details and more information can
be found at www.niko.eu under the "Help and advice" section.
4
EN
nv Niko sa Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: support@niko.be — www.niko.eu
All manuals and user guides at all-guides.com
5 x 95 mm (HxW)
90 x 77 mm (HxW)
through the DALI bus
8 – 12 m
360°
2.4 – 3 m
0 – +50 °C
IP20
class II devices, class I detector
CE marked
7. GUARANTEE PROVISIONS
• The period of guarantee is four years from the date of delivery. The delivery date is the invoice date of
purchase of the product by the consumer. If there is no invoice, the date of production applies.
• The consumer is obliged to inform Niko in writing about the non-conformity, within two months after
stating the defect.
• In case of a non-conformity, the consumer only has the right to a product repair or replacement free of
charge, which shall be decided by Niko.
• Niko shall not be held liable for a defect or damage resulting from incorrect installation, improper or careless
use, incorrect operation, transformation of the product, maintenance that does not adhere to the maintenance
instructions or an external cause, such as damage due to moisture or overvoltage.
• The compulsory regulations of the national legislation concerning the sale of consumer goods and the
protection of the consumer in the countries where Niko sells, directly or via sister companies, subsidiaries,
chain stores, distributors, agents or permanent sales representatives, take priority over the above-mentioned
rules and regulations.
Do not dump this product with the unsorted waste. Bring it to a recognised waste collection point. Together with producers
and importers, you have an important role to play in the advancement of sorting, recycling and reusing discarded electrical
and electronic appliances. In order to finance the waste collection and processing, the government levies a recycling
contribution in some cases (included in the purchase price of this product).
PM350-41659R16253