4 Mounting
Moisture
Transport
10
All manuals and user guides at all-guides.com
1
2
Fig. 3: Mounting horizontal
Switching point
1
Switching point (recommended mounting position, particularly for adhesive
2
products)
Use the recommended cables (see chapter "Connecting to power
supply") and tighten the cable gland.
You can give your LEVEL SWITCH 8110 additional protection against
moisture penetration by leading the connection cable downward in
front of the cable entry. Rain and condensation water can thus drain
off. This applies mainly to outdoor mounting as well as installation in
areas where high humidity is expected (e.g. through cleaning
processes) or on cooled or heated vessels.
Fig. 4: Measures against moisture penetration
Do not hold LEVEL SWITCH 8110 on the tuning fork.
LEVEL SWITCH 8110 • With extended status indication