New Construction Installation
6
Insert Mask and
Finish Ceiling
• Install ceiling material.
• Cut out around Housing.
CAUTION
IN ORDER TO PREVENT MOTOR/CONTROL DAMAGE:
If the blower was unplugged, power must be
disconnected (see page 2, WARNING item 2)
before inserting motor plugs into control assembly.
7
Install Grille
Plug in
1
Sensor
See Page 12 for Operations, Cleaning and Maintenance, and Troubleshooting.
All manuals and user guides at all-guides.com
2
ZB80M
ZB110M Installation Guide
n
Mask protects unit
during construction.
Remove before
installing Grille.