Page 5
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
1
GRD
120 VAC
WHT
LINE IN
BLK
MASTER
FUNCTION WALL SWITCHES
BLACK
WHITE
MASTER
SENSOR
ON/OFF
CONTROL
SWITCH*
SWITCH*
* purchase separately
All manuals and user guides at all-guides.com
Attach cable clamp to Knockout
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
2
Connect wires
SENSOR/
MANUAL-ON
CONTROL
STANDARD OR MULTI-
RED
ORANGE
BLUE
BROWN
GROUND
MANUAL
(green or bare)
ON
SWITCH*
SWITCH BOX
120 VAC
LINE IN
3
GRD
WHT
BLK
BLK
BLU
RED
RED
14/4
(IF ALL
WALL SWITCH
OPTIONS
ARE USED)
ORG
RECEPTACLES
KNOCKOUT
PLATE
ZB80M
ZB110M Installation Guide
n
4
Screw from
Parts Bag
WHT
FAN
BLK
SENSOR/
CONTROL
• See OPERATION section on page 12
for details.
• MASTER switch turns fan system
on and shuts it off for fan cleaning and
maintenance purposes.
• SENSOR/CONTROL switch turns
motion control automatic operation on/off.
• MANUAL-ON switch directly increases
fan operation to certified airflow rate.
• MASTER and SENSOR/CONTROL
switches can be combined (see page 10).
• MASTER switch along with or separate
from SENSOR/CONTROL switch may be
located where it is not easily accessed
for everyday usage; they may need to
be labeled and located where it can't be
turned on without being seen from fan to
comply with local and national codes.