All manuals and user guides at all-guides.com
RouterNode, GatewayNode
7 Signalling
Version
WNM.RN.R.IO
WNM.RN.CC.IO
WNM.RN.CR.IO
WNM.RN.EC.IO
EN
5. Connect the network cable or the RS-485 cable.
6. Connect the power supply.
The LED lights up in green.
9
7. Start up the RouterNode with the WaveNet Man-
ager and LSM.
9
LSM displays the network ID (Group ID/Member
ID) in the window "Administer WaveNet node".
RouterNode ready for use.
9
Signalling
Flashing, ~1.5 Hz
(green LED)
Flashing (green LED)
Continuous light (red
LED)
7. Signalling
Meaning
Ready to receive.
Data transmission.
Software
problem.
Problem with the
power supply.
Hardware
problem.
23 / 96