Typical Measurements
Clamp Around Wire
Clamp Around
Line Splitter
Notes:
• Clamp the jaw around one conductor only.
• Close the jaw completely.
• Center the wire in the jaw for highest accuracy.
Multimeter set to
read AC or DC voltage.
Note: Current flowing through
the jaw in the direction
indicated by the arrow
produces a positive reading.
Notes:
• The Greenlee 93-30 Line Splitter is divided. One section
renders amps; the other renders amps multiplied by 10.
• Close the jaw completely.
• Center the line splitter in the jaw for highest accuracy.
Multimeter set to
read AC voltage.