Start up
Description of the Appliance
1 Power cord with plug
2 Level sensor
3 Level sensor stopper
4 Carrying handle
5 Hose connection 1" (25.4 mm)
Preparing the Appliance
Illustration
 Screw the hose connection on to the
pump
Note
The shorter the hose, the higher the feed
rate.
 Push the hose on the hose connection
and fasten it with appropriate hose clip
Illustration
 In automatic operations mode, set the
required switching height by clamping
the level sensor cable in the stopper.
Illustration
 In manual operations mode, align the
level sensor upward (cable pointing
downward). Tip: Push the cable of the
level sensor like a loop through the han-
dle.
Illustration
 Place the pump on a level, stabile sur-
face in the liquid to be transported, en-
sure that it is standing firmly or immerse
it using a rope tied to the handle.
The suction area should not be blocked
fully or partially through the impurities.
All manuals and user guides at all-guides.com
The liquid level must at least be 3 cm (SCP
6000 / 7000) and 8 cm (SDP 7000) for the
pump to suck in liquids independently.
 Insert the mains plug into the socket.
In the automatic mode, the level switch au-
tomatically controls the pumping opera-
tions. The pump switches on or off when
the fluid level reaches the height that has
been set.
Ensure that the level sensor is not obstruct-
ed in any way.
In manual opertions the pump remains
switched on continuously.
Note:
Dry run leads to increased wear and tear;
do not leave the pump unattended when it
is running. Switch off the pump within 3
minutes of dry running.
 Rinse the pump with clean water after
Note
Contaminations can accumulate and lead
to malfunctions.
 Disconnect the main plug from the
The appliance is maintenance-free.
– 3
EN
Operation
Automatic operation
Manual operation
Finish operation
use.
socket.
Maintenance and Care
Maintenance