Télécharger Imprimer la page

EuroLite RGB Flood-1500 DMX Mode D'emploi page 25

Publicité

Les langues disponibles

Les langues disponibles

Channel 2 – Chaser
Value:
Characteristic:
0 – 21
Standard Chase (red, green, blue, yellow)
22 – 42
Bright Chase
43 – 63
Mood Chase
64 – 84
Spectrum Random Chase
85 – 105
Spectrum SequenceChase
106 – 126 Dynamic Chase
127 - 147
B – RG
148 – 168 R – BG
169 – 189 G – B
190 – 210 BR – G
211 – 231 B – R
232 - 255
BR - R
Channel 3 – Speed
Value:
Characteristic:
0 - 255
Slow - Fast
Channel 4 – Dimmer
Value:
Characteristic:
0 - 255
100% – 0%
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The lenses have to be replaced when they are obviously damaged,
so that their function is impaired, e. g. due to cracks or deep scratches!
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
CAUTION!
25/49
00026012.DOC, Version 1.2

Publicité