Troubleshooting Guide (cont.)
Symptoms
Probable
Causes
F.
G. The bleed
H. A flex hose
4. Low flow
A. Supply
(either AC or
DC).
B. Filters are
C. Aerator is
5. Constant
A. Battery life
water flow
(DC).
6. Constant
A. The power
water flow
(AC).
Kohler Co.
All manuals and user guides at all-guides.com
Recommended Action
Sensor
F.
Replace the sensor assembly.
eyes are
scratched.
G. Turn off the water supply.
hole in the
Remove valve cover and
diaphragm
diaphragm assembly. Clean any
is plugged
debris from the area and
or the
reinstall the components.
plunger is
stuck.
H. Check the flex hoses to make
is kinked.
certain they are not kinked. If
a flex hose is kinked,
disconnect it from the filter
cartridge, straighten, and
reconnect.
A. Check any filtration systems for
pressure is
blockage. Check incoming
low.
water pressure. Pressure should
be at least 20 psi (137 kPa).
B. Turn off water supply and
plugged.
disconnect fittings from supply
lines. Remove filter cartridges
from both supply lines. Clean
debris from screens and
reinstall the cartridges.
C. Remove the aerator and clean
plugged.
it. For calcium/mineral
deposits, soak the aerator
plastic insert in a 50:50 mixture
of vinegar and water. Soak only
the insert and no other
components.
A. Remove spout and replace
expired.
battery. Use a standard 6 Volt
lithium battery. This item is not
available from Kohler but can
be purchased at many stores
locally.
A. Once the power is stable,
source is
unplug the unit and plug back
unstable,
into wall.
off, or the
circuit is
blown.
21