Battery Location
Premium AA alkaline batteries
are required when C-wire is
not available. When C-wire is
available, the batteries provide
a back-up source of power (this
will maintain the clock in the
event of a power outage).
1.) Gas/Elec Switch
If the system is a heat pump or electric furnace, the GAS/ELEC Switch must be set to
Elec. If your system is a gas or oil furnace, the switch must be set to Gas.
2.) O/B Terminal Switch
The O/B switch on this thermostat is factory set to the O position. This will accommodate
the majority of heat pump applications, which require the changeover relay to be
energized in Cool. If the heat pump being installed requires a B terminal, to energize the
changeover relay in Heat, the O/B switch must be moved to the B position.
3.) RC/RH Jumper Wire
This thermostat electrically connects the RC and RH terminals so a jumper wire is not
required. If the application provides a separate wire for RC and RH, clip the RC/RH
jumper. This will isolate both terminals so they can be independently used.

INSTALLER MENU

To prevent changes that may affect system performance, this thermostat has an INSTALLER'S
MENU and an USER MENU. The INSTALLER'S MENU provides access to every option, while
the USER MENU provides access to items that will not affect system performance. To access
the INSTALLER'S MENU press the Menu button for 8 seconds. The display will show item 30 in
the table below. Use Next and Back to navigate through menu items. Press
a menu setting.
Installer's Menu #
(Hold Menu 8 Seconds)
30
35
50
65
66
74
(Installer Menu continued on next page)
Description
Heat Cycle Rate (how often
the heat will turn on)
Cool Cycle Rate (how often
the cooling will turn on)
Compressor Lockout
(protects the compressor
from short cycling)
Maximum Heat Limit
(maximum set point for heat mode)
Minimum Cool Limit (minimum
set point for cool mode)
Schedule Type (set as either 7-Day,
5-1-1 Day or Non-Programmable)
Default Setting
(flashing icons)
MEd
MEd
OFF
99
45
5
or
to change
Settings
(Press
or
)
SLO – slow
MEd – medium
FAS – fast
SLO – slow
MEd – medium
FAS – fast
On – 5 minute display
OFF – no delay
47 to 99
45 to 97
7 – 7 Day
5 – 5-1-1 Day
0 – Non Programmable
3
1
2
3