Télécharger Imprimer la page

Sime Home Plus Manuel D'installation Et D'utilisation page 6

Publicité

Les langues disponibles

Les langues disponibles

2.4
Wall mounting
After having taken the Sime HOME PLUS Remote Control out of
its packaging:
– Use a screwdriver to push the fastening tab (1) to release
the base (2) from the user interface (3) making sure that the
screwdriver does not penetrate.
– Separate the 2 parts
6
All manuals and user guides at all-guides.com
3
2
1
– Position the Bus communication cable (4), Open Them, be-
tween the boiler and the Remote Control
– Connect the boiler to the terminals (5) (Cable: 2 x 0.75 mm
unpolarised, Max. length: 50 m)
– Arrange the communication cables required for connecting
a phone dialler for remote management to the terminals (6)
if necessary
4
5
EN
2
6

Publicité

loading

Ce manuel est également adapté pour:

8092282