System inertia
This is a parameter which adjusts the reaction time of the ad-
justment algorithm, to be associated with inertia or with the
size and type of building and the heating system.
Flow Temp. min. set
It is the lower limit of the calculated flow temperature (use-
ful in the case of low efficiency systems with low calculated
temperatures)
Antifreeze enable
: enable the antifreeze protection program
YES setting
NO setting: the heating will remain off when in the function
mode OFF, SUMMER and in periods of Reduced mode AUTO if
the room sensor is disabled.
Antifreeze set
This is the room temperature (antifreeze) below which the de-
vice makes a heating request at the minimum flow set. The
request remains active until the room temperature has ex-
ceeded the "antifreeze temperature + 0.6°C"
Room probe offset
This is the value used to correct the room temperature read-
ing by the sensor inside the device.
Anti-legionella Function
This is the function used to protect against the development of
bacteria in the water. There are three possible settings - Acti-
vation - Day - Time.
All manuals and user guides at all-guides.com
4.3
From the "main screen"
– Press the button
– Press the encoder
– Rotate the encoder
Settings from the MODE button
Zona
Gi 18 Set 2014
Off
Menu
Mode
Rotate the encoder
"Function mode".
Mode (eg. "Winter")
Summer
Winter
Hot water
Heating
Holiday function
Esc
to confirm the highlighted "Mode"
click
and go into the "rows"
Winter
Hot water
Heating
Holiday function
Esc
to select "Heating"
10:30
Modo
to go into the screen to select
to select one
Off
MAN 40°C
MAN 20.0°C
OFF
Back
MAN 40°C
MAN 20.0°C
OFF
Back