Télécharger Imprimer la page

American Standard A8001L-RHO Instructions D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

A8003L-LHO
LEFT HAND
8"
OUTLET
(203mm)
17-1/2"
(445mm)
36"
(914mm)
1-1/2"
(38mm)
2-1/2"
(64mm)
1
Ensure that the floor and stud walls are square and plumb on a level
floor as shown in Figure A. Provide a 5" x 5" (127 x127 mm) opening in
the floor for the drain and refer to the product rough-in for actual drain
location. Draw a line 3-1/2" (89 mm) [model A8003L-LHO/A8003L-RHO
draw a line 4" (102mm)] above the level subfloor on the wall studs at
each side of the opening.
60"
(1524mm)
3-1/4"
(83mm)
FRONT
TOP VIEW
2" (51mm)
THRESHOLD DEPTH
RIGHT SIDE
A8004L-CO
(610mm)
17-1/2"
(445mm)
36"
(914mm)
1"
(25mm)
2-1/2"
(64mm)
A8003L-RHO
1-1/2"
(38mm)
2-1/2"
(64mm)
48"
(1219mm)
24"
3-1/4"
(83mm)
FRONT
TOP VIEW
2" (51mm)
THRESHOLD DEPTH
RIGHT SIDE
FIGURE A
- 2 -
60"
(1524mm)
8"
(203mm)
3-1/4"
(83mm)
FRONT
TOP VIEW
2" (51mm)
THRESHOLD DEPTH
RIGHT SIDE
CENTER
OUTLET
MARK STUDS 2-1/8" (54mm)
ABOVE LEVEL SUBFLOOR
90°
2" (51mm)
C/L
PVC Waste Pipe
(See Product Rough-In for Drain Location)
RIGHT HAND
OUTLET
17-1/2"
(445mm)
36"
(914mm)
90°
Opening 6" x 6"
(152 x152mm)
755470-100 Rev. 4 (7/22)

Publicité

loading

Ce manuel est également adapté pour:

A8001l-lhoA8002l-rhoA8002l-lhoA8003l-rhoA8003l-lhoA8004l-co