Télécharger Imprimer la page

Maison Berger Aroma Relax Mode D'emploi page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
WARNING. This device may be used by children over the age of 8 and by persons with
reduced physical, sensory or mental capabilities or devoid of experience or knowledge,
if they are correctly monitored or if the instructions relating to the safe use of the device
have been given to them and if the risks have been understood. Children should not play
with the device. User cleaning and maintenance should not be performed by children
without supervision. If the power cable is damaged, it must be replaced by a cable or
a special set available from the manufacturer or its after-sales service. The device must
only be used with the power supply model: A062-501200PB provided with the device. The
device must only be used with fragrance refills for the Maison Berger Paris electric diffuser.
The use of other substances may lead to a toxic risk or a risk of fire.
• Do not use used water or hard water containing impurities to clean the reservoir in order to avoid damage to the ultra-sound plate.
• For better conservation, store the Maison Berger Paris fragrance refills away from direct light and at ambient temperature.
• Never shake the fragrances refills for the Maison Berger Paris electric diffuser before use.
• When the level of filling exceeds the maximum level of the visual indicator on the reservoir, this can decrease the intensity of the mist or even cause it to completely shut down. If
the water level is too low, the diffuser will stop automatically and the light will switch off.
Always switch off and disconnect the diffuser for cleaning.
• Clean the reservoir between each fill with clear water and with the help of a soft cloth
• To clean the ultra-sound ceramic, remove the protective plastic cap and then clean it with a soft cloth
• To ensure good performance, clean the reservoir before using a new fragrance.
• Clean the surface, the cover and the exterior of the diffuser with a soft cloth if necessary and store in a dry place.
• If the perfume starts to build up on the ultra-sound plate, gently wipe it with the help of a cleaning sponge or a soft cloth, without using any metallic objects.
• If the perfume starts to build up on the cover, gently wipe it using only mild soap and water.
• Do not directly rinse the diffuser or put it in water. Do not pour water or other liquids or debris in the slot, especially when removing excess perfume.
• Do not move, shake or tilt the diffuser when it is filled with the fragrance, plugged in or in operation. Similarly, the various parts of the diffuser cannot be dismantled when in
operation.
• Hold the diffuser by the bottom when moving it.
• Never remove the cover during diffusion and do not place your fingers or any other object in the perfume during use of the device.
• Keep the power supply and power cable away from heated surfaces.
• Unplug the device when filling, cleaning or moving the diffuser, especially if it has not been used for a long time. Never touch the adaptor with wet hands. Never wrap or cover
the adaptor with fabric, paper, etc.
• Keep away from household pets.
• Keep the diffuser dry, away from heat and water and protected from dust and moisture.
• For indoor use only.
• Do not voluntarily place your eyes, nose or mouth near the perfumed mist.
• To avoid any risk of fire, electric shock or any damage or injury, do not place the diffuser: in dusty areas, on sloping, unstable or uneven surfaces. In smoky areas, in rooms in which
the temperature is above 40°C.
• The button battery used in the remote control may present a risk of fire or chemical burns if it is misused or replaced incorrectly. Do not recharge it, do not dismantle it, do not heat
the device at a temperature greater than 100°C and do not incinerate it. Replace the battery with an equivalent CR2025 battery. Keep the old battery out of the reach of children
and dispose of it quickly.
2 year guarantee Consult the terms of warranty on our site:
www.maison-berger.com
Due to poor configuration of the diffuser or a malfunction caused by poor maintenance, please refer to the following solution:
Sign of
No mist vaporisation
No mist or gentle mist vaporisation, even with sufficient
failure
after switching on
If the diffuser
flashes 5 times when
There are
switched on, you are
pollutants
Analysis of
alerted that there
on the
problems
is an insufficient
ultra-sound
amount of perfume
plate
in the reservoir.
Add sufficient
Clean the
Solution
perfume to the
ultra-sound
reservoir
plate
ENGLISH - INSTRUCTIONS
NOTES
CLEANING
SAFETY
WARRANTY
MALFUNCTION (TROUBLESHOOTING)
Appearance of
perfume in the
perfume
The
amount of
perfume
The mist
period of use until
exceeds
The slot
output
empty, it is normal
the
may be
may be
for there to be
maximum
blocked
blocked
a slight perfume
level of the
reservoir
(80ml)
Discard the re-
maining fragrance
Remove
Remove
and clean using a
the
Empty the
the ob-
soft cloth before
obstruc-
excess
struction
refilling with a new
tion from
perfume
from the
fragrance for the
the mist
slot
Maison Berger
output
The remote control does not
reservoir after
work
extinction
At the end of
The diffuser
The battery
does not detect
is used up
the remote
control
residue
Point the re-
mote control in
Replace the
the direction of
battery with
the diffuser and
a CR2025
move closer to
battery.
the diffuser (less
Paris electric
than 3 metres)
diffuser
Sparks when plug-
No electricity
ging in
The USB cable was
first plugged into the
The power
The USB
adapter, and then
button has
cable is not
the socket before
not been
connected
inserting the plug of
pressed
the DC adapter
Begin by inserting
the DC plug into
the diffuser, then
Press the
connecting the
Reinsert
power
USB cable into the
correctly
button
adapter, and finally
connect to a power
socket.

Publicité

loading