Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

®
ALLURE
WS2 SERIES RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society of Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range
hood with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when flambeing food
(i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
All manuals and user guides at all-guides.com
FOR DOMESTIC COOKING ONLY
!
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. For best capture of cooking impurities, your range hood should
be mounted so that the top of the hood is 24-30" above the
cooking surface.
4. Please read specification label on product for further information
and requirements.
Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 6.
NOTE
If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
TABLE OF CONTENTS
This manual is divided into sections as follows:
• "PREPARE HOOD LOCATION"
Run ductwork from roof or wall cap, and electrical wiring
from service panel - to installation location
• "PREPARE THE HOOD"
Get your hood ready for installation
• "CONNECT WIRING"
Make electrical wiring connections to hood
• "INSTALL HOOD"
Secure hood to cabinet and ductwork - install bulbs and
filters
• "OPERATION"
How to use the hood controls
• "CLEANING"
Keep your hood in top working condition
• "SERVICE PARTS"
Part numbers and exploded view of hood components
• "WARRANTY"
One-year limited warranty and how to contact us
ALLURE
®
WS2 SERIES
RANGE HOOD
Page 1
Patent No.:
US D450, 829 S
!

Publicité

loading

Sommaire des Matières pour NuTone ALLURE WS2 Serie

  • Page 1 All manuals and user guides at all-guides.com ALLURE ® WS2 SERIES RANGE HOOD Page 1 ® ALLURE WS2 SERIES RANGE HOOD Patent No.: US D450, 829 S READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY WARNING CAUTION TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 1.
  • Page 2 All manuals and user guides at all-guides.com ALLURE ® WS2 SERIES RANGE HOOD Page 2 PREPARE HOOD LOCATION PREPARE THE HOOD ROOF CAP 3¼" X 10" FILTERS (For vertical discharge) SOFFIT HOUSE WIRING CABINET (Top or Back of hood) WALL CAP Remove tape holding Filters in place.
  • Page 3 All manuals and user guides at all-guides.com ALLURE ® WS2 SERIES RANGE HOOD Page 3 PREPARE THE HOOD PREPARE THE HOOD AIR CHUTE Remove Air Chute - held in place with one (1) screw. NOTE: Be careful not to disconnect any wires.
  • Page 4 All manuals and user guides at all-guides.com ALLURE ® WS2 SERIES RANGE HOOD Page 4 PREPARE THE HOOD PREPARE THE HOOD TIES SCREW BLOWER RETAINING WHEEL RING SMALL DIAMETER RING SECTIONS MOTOR STOP SLOTS EDGE 10 Non-Ducted Installations Only: Require a Performance Ring to be attached to the blower wheel.
  • Page 5 All manuals and user guides at all-guides.com ALLURE ® WS2 SERIES RANGE HOOD Page 5 INSTALL HOOD CONNECT WIRING WARNING: To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power from being switched on accidentally.
  • Page 6 All manuals and user guides at all-guides.com ALLURE ® WS2 SERIES RANGE HOOD Page 6 NON-DUCTED FILTERS OPERATION If hood is to be installed Non-Ducted: Purchase a set of (2) Non-Ducted Filters from your local distributor or retailer and attach them to the aluminum mesh filters.
  • Page 7 All manuals and user guides at all-guides.com ALLURE ® WS2 SERIES RANGE HOOD Page 7 SERVICE PARTS KEY NO. PART NO. DESCRIPTION R740013 Damper/Duct Connector (includes hardware) R602017 Screw, #8-18 x ¼ Hex* (2 in package) R334755 Motor Capacitor (includes wire nuts & hardware) R501031 Isolation Transformer R627501...
  • Page 8 IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 9 All manuals and user guides at all-guides.com HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE ® WS2 SERIES ® ALLURE RANGE HOOD Page 9 HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE ® Brevet N US D450, 829 S LISEZ ET CONSERVEZ CES DIRECTIVES CONÇUE UNIQUEMENT POUR LA CUISSON DOMESTIQUE AVERTISSEMENT ATTENTION...
  • Page 10 All manuals and user guides at all-guides.com HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE ® WS2 SERIES ALLURE ® RANGE HOOD Page 10 PRÉPAREZ L’EMPLACEMENT PRÉPAREZ LA HOTTE CAPUCHON DE TOIT CONDUIT DE 3¼ po X 10 po FILTRES (Pour évacuation verticale) SOFFITE FIL DU PANNEAU D'ALIMENTATION ÉLECTRIQUE (Branché...
  • Page 11 All manuals and user guides at all-guides.com HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE ® WS2 SERIES ® ALLURE RANGE HOOD Page 11 PRÉPAREZ LA HOTTE PRÉPAREZ LA HOTTE GOULOTTE Enlevez la goulotte maintenue par une (1) vis. REMARQUE : Prendre garde de ne débrancher aucun fil.
  • Page 12 All manuals and user guides at all-guides.com HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE ® WS2 SERIES ® ALLURE RANGE HOOD Page 12 PRÉPAREZ LA HOTTE PRÉPAREZ LA HOTTE ATTACHES PATTE ROUE DU ANNEAU VENTILATEUR EXTRÉMITÉ DE RETENUE FAIBLE DIAMÈTRE ANNEAU SECTIONS FENTES...
  • Page 13 All manuals and user guides at all-guides.com HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE ® WS2 SERIES ® ALLURE RANGE HOOD Page 13 BRANCHEZ LES FILS INSTALLEZ LA HOTTE D’ALIMENTATION ÉLECTRIQUE AVERTISSEMENT: Afin de prévenir les risques d’électrocution, assurez-vous que le courant ait été interrompu au panneau d’alimentation principal.
  • Page 14 All manuals and user guides at all-guides.com HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE ® WS2 SERIES ® ALLURE RANGE HOOD Page 14 FILTRES SANS CONDUIT FONCTIONNEMENT Si la hotte est installée sans conduit : Procurez-vous un ensemble de 2 filtres pour installation sans conduit et fixez-les aux filtres d’aluminium.
  • Page 15 All manuals and user guides at all-guides.com HOTTE DE CUISINIÈRE DE LA SÉRIE ALLURE ® WS2 SERIES ALLURE ® RANGE HOOD Page 15 PIÈCES DE REMPLACEMENT SCHÉMA PIÈCE DESCRIPTION R740013 Raccord de conduit avec registre (avec vis d’assemblage) R602017 Vis n 8-18 x ¼...
  • Page 16 GARANTIE LIMITÉE DE UN AN DE NUTONE NuTone garantit à l’acheteur consommateur original de ses produits qu’ils sont exempts de vice de matériaux ou de fabrication pour une période de un an à compter de la date d’achat original. IL N’Y A PAS D’AUTRES GARANTIES, EXPRIMÉES OU IMPLICITES, INCLUANT MAIS NON LIMITÉES AUX GARANTIES IMPLICITES DE QUALITÉ...