CONNECT WIRING
WARNING: To reduce the risk of electric shock,
make sure power is switched off at the service
panel. Lock or tag service panel to prevent power
from being switched on accidentally.
1
Connect House Wiring (120 VAC) to hood. Use a piece of
Cardboard to protect the cooktop, if necessary.
2
Connect house BLACK to hood BLACK wire, house WHITE
to hood WHITE wire, and house ground under GREEN
Ground Screw. Securely tighten cable clamp onto house
wiring.
All manuals and user guides at all-guides.com
HOUSE
WIRING
(120 VAC)
CARDBOARD
(Use to protect
cooktop)
GREEN
GROUND
SCREW
INSTALL HOOD
KEYHOLE (4)
1
Hang hood from (4) Mounting Screws. Slide hood towards
wall until mounting screws are engaged in narrow end of
(4) Keyholes. Tighten mounting screws securely. A long
screwdriver works best.
2
Replace bottom cover.
3
Connect ductwork to hood. Use Duct Tape to make joints
secure and air tight.
4
Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16,
40 W Maximum Incandescent Bulbs. Purchase bulbs
separately.
!
CAUTION:
Bulbs may be hot! Refer to bulb packaging
for further information.
5
Replace filters, turn on power at service panel, and test for
proper operation.
ALLURE
®
WS2 SERIES
RANGE HOOD
Page 5
MOUNTING SCREW (4)
DUCT
TAPE
PAR20,
50W MAX.
HALOGEN
BULB (2)
- or -
R16,
40W MAX.
INCANDESCENT
BULB (2)