ORGAPACK CR 208 P
5
The tool always has to be disconnected
from the air supply, before maintenance- or
repair work is performed.
5.1 ADJUSTING THE STRAP TENSION
The air pressure is regulated by the pressure
regulator on the maintenance unit. With running air
motor, the pressure should be minimum 4 bar (60 psi)
and maximum 6 bar (90 psi).
5.3 SETTING THE CLEARENCE BETWEEN
TENSIONING WHEEL AND TENSION PLUG
Space between tensioning wheel (7/2) and tension plug
(7/3) must have 0,1–0,25 mm (.0039"–.0098").
– Disconnect the tool from the air supply.
– Loosen set srew (7/1).
– The space can be adjusted by turning the tension
plug (7/3), with a screwdriver. For less space turn
clockwise, for more space turn counterclockwise.
– Tighten set screw (7/1). The pointed head of the set
screw must be located in one of the notches of the
toothed plate.
5.4 CLEANING/REPLACING THE
TENSIONING WHEEL
Remove
– Disconnect the tool from the air supply.
– Loosen two cylinder screw (8/1).
– Carefully remove the bearing plate (8/2) from tension
shaft.
– Take off the counter washer (8/3) and the tensioning
wheel (8/4). Check the tensioning wheel, clean or
replace if necessary.
Install
– Install the parts in reverse order.
18
PREVENTIVE AND CORRECTIVE MAINTENANCE
5.2 CLEANING THE TOOL
– The tool should be regulary cleaned. The easiest
way to do this, is to use compressed air and to blow
out the dust (wear eye protection).
Fig. 7
4
3
Fig. 8
1
2
3
0,1–0,25 mm
(.0039"–.0098")
2
1
08.05/WE