Télécharger Imprimer la page

Waeco AirConServiceCenter ASC5500G RPA Notice D'utilisation page 139

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 212
ASC5500G RPA
Problem
The display shows
„00002"
The display shows
„00003"
The display shows
„00004"
The display shows
„00005"
12
Technical data
Item number:
Dimensions (width x height x depth)
Weight:
Power supply:
Refrigerant extraction rate:
Vacuum pump output:
Hermetic compressor output:
Drier filter output:
Filling cylinder accumulator capacity:
Noise emission:
Accuracy of the electronic scale for refrigerant:
Accuracy of the electronic scale for old/new oil:
Accuracy of the electronic scale for UV additive:
Operating temperature range:
EN
Cause
The readings are excessively
high.
Calibration with the ambient
air failed.
The device is operating out-
side the recommended tem-
perature range.
The refrigerant sample has a
very high content of air or the
amount of refrigerant was too
low for testing.
Technical data
Remedy
Keep possible electrical
sources of interference, such
as mobile phones or welding
equipment, away from the
device.
Ensure the device is ade-
quately ventilated.
Leave any leaking refriger-
ant to drain off.
Only use the device in tem-
perature-controlled rooms
(10 °C – 45 °C).
Ensure sufficient ventilation.
Make sure that there is
enough refrigerant pressure.
Make sure that all the hoses
are connected, not kinked
and free of oil.
AirConServiceCenter
ASC5500G RPA
9103301882
560 mm x 1300 mm x 650 mm
100 kg
230 V/240 V–50 Hz/60 Hz
30 kg / hr
5 cars / hr
0.32 kW
150 kg
16 kg
55.5 dB (A)
± 10 g
± 1 g
± 1 g
+ 5 °C to + 50 °C
139

Publicité

loading