Télécharger Imprimer la page

Waeco AirConServiceCenter ASC5500G RPA Notice D'utilisation page 128

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 212
Service tasks
9.7
Meter readings
I
NOTE
The unit saves various meter readings. To access the total values –
consecutively, since the unit was produced – enter the menu "Other
selections" – "Service" and enter the code "7783". Use the cursor
keys  or  to select a particular entry.
These meter readings cannot be reset. To access the meter readings
which can be reset, enter the code "7782" under "Service". Also see
chapter "Changing the vacuum pump oil" on page 125 or chapter
"Changing the dryer filter" on page 120.
"R1234 from system" indicates how many grams of refrigerant have
been extracted from air conditioning systems using the menu item "Short
selection" or "Free selection" since the last reset (see date).
"R1234 from tank" indicates how many grams of refrigerant were added
to the unit using the menu item "Int. vessel filling" since the last reset (see
date).
"R1234 to system" indicates how many grams of refrigerant have been
filled into air conditioning systems using the menu item "Short selection"
or "Free selection" since the last reset (see date).
"Vacuum time" indicates how long the vacuum pump has operated
since the last reset (see date).
128
R1234 from system
Total
g.
STOP-EXIT
R1234 from tank
Total
g.
STOP-EXIT
R1234 to system
Total
g.
STOP-EXIT
Vacuum time
Total
min.
STOP-EXIT
ASC5500G RPA
07/03/17
1455
07/03/17
3395
07/03/17
1200
07/03/17
79
EN

Publicité

loading