1.0 general information
For elevations between 2,000ft (610m) and 4,500ft (1372m) above sea level, this appliance must be
de-rated by 10% using the certifi ed high altitude kit. When the appliance is installed at elevations above 4,500ft
(1372mm), and in the absence of specifi c recommendations from the local authority having jurisdiction, the
certifi ed high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (305m).
Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane. Expansion /
contraction noises during heating up and cooling down cycles are normal and to be expected.
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and
must be installed.
GDS50: This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for
mobile homes. The natural gas model is suitable for installation in a mobile home that is permanently positioned on
its site and fueled with natural gas.
GS50: This appliance is approved for bedroom and bed-sitting room installations.
1.1
rates and effi ciencies
Altitude (FT)
Max. Input (BTU/HR)
Max. Output Steady State (BTU/
HR)
Effi ciency (w/the fan on)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow
Conditions)
* Max. inlet pressure not to exceed 13".
Installer, please fi ll out the following information:
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
NG
0-2000
44,000
31,200
77%
4.5" (11mb)
Water Column
7" (17mb)
Water Column *
3.5" (9mb)
Water Column
standard checklist
Propane:
GDS50-1PSB
GS50P
GS50
P
0-2000
0-2000
40,000
44,000
30,000
37,000
78%
84%
11" (27mb)
4.5" (11mb)
Water Column
Water Column
13" (330.2mm)
7" (17mb)
Water Column
Water Column
10" (25mb)
3.5" (9mb)
Water Column
Water Column
GDS50
NG
P
0-2000
40,000
34,400
86%
11" (27mb)
Water Column
13" (330.2mm)
Water Column
10" (25mb)
Water Column
W415-1427 / C / 06.05.19