Mounting the extractor hood
5.1
Control elements
No. in
fig. 2,
Description
page 3
1
Filter
2
Fan On/Off switch
3
Light On/Off switch
4
Lamps
6
Mounting the extractor hood
Note on installation location
The extractor hood should preferably be mounted above the cooking zone and built
into a suspended cabinet if possible. The distance between the gas hob flame and
the extractor hood must be at least 50 cm.
The fan should be mounted on the roof on a level surface. When mounted on a
sloping surface, the roof hood must be rotated so that one of the three water
drainage holes is directed toward the incline. A tilt angle up to 20° will not affect the
performance of the fan when the motor is not running.
6.1
Mounting the fan
➤ Select an appropriate installation location for the fan on the roof.
➤ Draw the location and size of the opening of 105 mm diameter (fig. 3, page 4).
➤ Pre-drill and cut out the hole on the roof carefully with a keyhole saw or similar
tool.
➤ Place the fan on the opening and mark the six screw holes.
➤ Apply a thin ring of a permanently elastic sealing material around each hole.