Failure
Possible causes
- Nails are inaccurately fed
into the Blade Guide
- Incorrect nails are loaded
- Worn driver blade
The driven nail
is bent
- The wood is too hard
- The wood is too hard
- Air pressure too low
The driven
- Worn or broken driver
nails do not
blade
fully pene-
trate the work
- Incorrect driving depth
adjustment
piece (heads
protrude)
- Defective piston ring
(worn or broken)
- Defective inner surface of
cylinder (worn or rough)
- Nails are inaccurately fed
into the blade guide
- Incorrect nails are loaded
- Worn tip of the driver
blade
Nails clog
within the
- Worn guide groove of the
ejecting gate
blade guide
- Workpiece material is too
hard
Please send the tool back to the tool manufacturer / distributor if failure other than those as
tabulated above occurs.
Check method
Refer to item on the pre-
vious page
Check if the driver blade is
extremely worn or not
Check if the nails bend on
softer wood or not
Carry out idle driving and
check if the driver blade
protrudes from the blade
guide nose
Check if the tip of the driver
blade is excessively worn
or not
Disassemble the output
unit and check the inside
and outside surfaces of the
piston ring and cylinder
Refer to first item
Carry out idle driving and
check if blade tip if worn or
not
Check the wear of the
blade guide
27
Counter measures
- Refer to item on the pre-
vious page
- Replace the driver blade
- Stop using the tool
- Stop using the tool
- Adjust the air pressure
- If the driver blade does
not protrude from the blade
guide replace
- Adjust the guide plate to
the appropriate position.
- Replace the defective
parts
- Refer to first item
- Use designated nails
- Replace
- Replace
- Stop using the tool