WARNING
Keep hands and body away from the discharge area of the tool when connecting the
air supply and always disconnect the tool when servicing, adjusting, cleaning and
when the tool is not in use.
III. OPERATING INSTRUCTIONS
3.1 Loading fasteners (refer also to the technical data)3.1.1 side loading magazine
Open the magazine cover, load the fastener, close the magazine.
3.1.2 rear loading magazine
For 2 steps type, slide the nail strip into the magazine, pull the pusher until it is behind the
nail, release the pusher and ensure proper engagement of the pusher on the nail.
For 3 steps type, pull the pusher to the back and keep it on the latch mechanism. Load the
fastener and release the pusher.
3.1.3 top loading magazine Pull the pusher to the back of the magazine and keep it on the
latch mechanism. Load the fastener and release the pusher.
WARNING Point away the nozzle when loading or unloading the fastener. Disconnect the
hose before loading the fastener.
3.2 General operating instructions
3.2.1 Types of actuating and triggering systems.
For tools without a contact safety,
Single action actuation : An actuating system where the trigger has to be actuated for each
driving operation.
Single action with simple safety :
A safety latch is built into the trigger enabling the user to disengage it when it is not in use.
For tools with a contact safety installed
Dual action safety / contact safety (Contact actuation):It will be necessary to activate the
contact safety mechanism as well as the triggering device in order to fire a fastener. By kee-
ping the trigger activated and activating the contact safety a fastener is fired, this allows for
high speed firing, also known as bump firing
Single Sequential Trip fire (Single-sequential actuation): Fasteners can only be fired by first
activating the contact safety(by holding the tool against the workpiece) and then by pulling
the trigger, thereafter any further driving operations can only be actuated after the trigger
has been returned to the starting position. The sequential trip tool allows exact fastener
location without the possibility of driving a second fastener due to recoil.
Changing the trigger :
To change the trigger, simply remove the trigger pin, remove the trigger and insert the re-
quired one, replacing the trigger pin to hold it in place.