Technical specifications
Panther FC 20 - 30 (IP44)
Item
Type
Output
number
steps
[kW]
PNF20
334031
0/10/20
334032
PNF2023 0/10/20
PNF30
334033
0/10/20/30 2250/2800 78
334035
PNF3023 0/10/20/30 2250/2800 78
*
) Sound power (L
) measurements according to ISO 27327-2: 2014, Installation type E.
1
WA
*
) Sound pressure (L
2
pA
absorption area: 200 m². At lowest/highest airflow.
*
) ∆t = temperature rise of passing air at maximum heat output and lowest/highest airflow.
3
) Approved for 380V/3ph/60Hz. Product performance for 380V/3ph/60Hz will differ from stated data.
*
4
Ecodesign Regulation (EU) 2015/1188
Ecodesign Regulation (EU) 2015/1188
Type
Heat output
Nominal heat output [kW]
Minimum heat output [kW]
Maximum continous heat output [kW]
Auxiliary electricity consumption
At nominal heat output [kW]
At minimum heat output [kW]
In standby mode [kW]
Features
Fan assisted output
Electronic room temperature control plus week timer
Room temperature control, with open window detection
Distance control option
Adaptive start control
EN: For translation of the English texts used, see the respective language pages.
FR: Pour la traduction des textes en anglais, consultez la page correspondante à la langue souhaitée.
DE: Für die Übersetzung der verwendeten Texte in englischer Sprache, siehe die entsprechenden
Sprachseiten.
SE: För översättning av de engelska texter som används, se respektive språksidor.
NO: For oversettelse av de engelske tekstene, se de respektive språksidene.
DK: For oversættelse af de engelske tekster, se siderne for de respektive sprog.
FI:
Suvuilla olevien enlanninkielisten sanojen käännökset löytyvät ko. kielisivuilta.
NL: Voor een vertaling van de gebruikte Engelse teksten, zie de pagina's van de resp. taal.
ES: Consulte la traducción de los textos en inglés que las acompañan en las páginas del idioma
correspondiente.
IT:
Per le traduzioni dei testi scritti in inglese, vedere le pagine nelle diverse lingue.
PL: Tłumaczenie wykorzystanych tekstów angielskich znajduje się na odpowiednich stronach językowych.
RU: Перевод встречающегося там текста приведен в разделе RU.
Panther FC 20-30
Airflow
Sound
power *
[m³/h]
[dB(A)]
2250/2800 78
2250/2800 78
). Conditions: Distance to the unit 3 metres. Directional factor: 2. Equivalent
Sound
∆t*
Motor
3
pressure*
1
2
[dB(A)]
[°C]
[W]
51/62
27/21
150
51/62
27/21
150
51/62
32/40
150
51/62
32/40
150
PNF20
PNF2023
20
20
10
10
20
20
0,004
0,004
0,004
0,004
0,0005
0,0005
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Voltage
Amperage
[V]
[A]
400V3N~*
29,5
4
230V3~
50,2
400V3N~*
43,9
4
230V3~
75,3
PNF30
PNF3023
30
30
10
10
30
30
0,004
0,004
0,004
0,004
0,0005
0,0005
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Weight
[kg]
28
29
31
33
7