CONNECTING THE FEEDER
CONNECTING THE FEEDER CABLE
CABLE
WARNING: If the power supply cable is
To connect the feeder cable to the cook-
damaged, it must be replaced only by
er it is necessary to:
an authorised service agent in order to
avoid a hazard.
– Remove the two screws that hold
shield A behind the cooker.
To connect the feeder cable to the cooker
it is necessary to:
– Open completely the cable clamp D.
•
– Position the U bolts onto terminal block
Remove the two screws that hold
shield "A" behind the cooker.
B (fig. 10.1) according to the diagram
in fig. 10.2a, 10.2b, 10.2c.
•
Open completely the cable clamp "D".
– Insert the feeder cable into the cable
•
Position the U bolts onto terminal
clamp D. The supply cable must be
block "B" (fig. 9.1) according to the
of a suitable size (see the section
diagram in figs. 9.2, 9.3.
"Feeder cable section").
•
Insert the feeder cable into the cable
– Connect the phase and earth cables
clamp "D". The supply cable must
to terminal B according figures 10.2a,
be of a suitable size (see the section
10.2b, 10.2c.
"Feeder cable section").
– Pull the feeder cable and block it with
•
Connect the phase and earth cables
the cable clamp D.
to terminal "B" according figures 9.2,
9.3.
– Re-mount shield A.
•
Pull the feeder cable and block it with
N.B. The earth conductor must be left
the cable clamp "D".
about 3 cm longer than the others.
•
Re-mount shield "A".
N.B. The earth conductor must be left
about 3 cm longer than the others.
D
Fig. 9.1
FEEDER CABLE SECTION
"TYPE H05RR-F"
230 V ac
400 V 3N ac
400 V 2N ac
(**) Connection with wall box connection.
–
–
B
A
3 x 6 mm
5 x 2,5 mm
4 x 6 mm
Diversity factor applied.
A diversity factor may be applied to the
total loading of the appliance only by a
suitably qualified person.
(**)
2
(**)
2
(**)
2
211