Radialight BALI Manuel D'utilisation page 26

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2. Wall mounting
Only fix the heater in vertical position with the air outlet grid downward;
This heater is fitted with a double electrical insulation circuit (class II) and therefore does not require an earth connection.
This heater must be correctly installed in compliance with the regulations in force in the country of installation.
In wet spaces like bathrooms or kitchens, the connection terminal must be installed at least 25 cm above the floor. The
electrical connection to the power supply must also be fitted with a two-pole switch with a minimum gap between the
contacts that allows complete disconnection according to excess voltage III category conditions.
Always make observe the minimum distances from walls, furniture and/or objects, as indicated in picture 3. Never install
the product so that the distance between the floor and the lower side of the product is less than 30cm:
-
Drill three 6 mm diameter holes in the wall, as shown in picture 4
-
Insert the three wall plugs supplied with the product
-
Insert the 2 upper screws, contained in the same bag, taking care to leave a distance of 8 mm between the head
of the screws and the wall;
-
Gripping the heater firmly, hook it onto the two screws; CAUTION! Before releasing the heater make sure it is
attached to the 2 screws.
-
Then secure the product with the lower screw.
3.
Filter
This product is fitted with a filter to protect the heating element from dust and dirt.
The filter is removable to be easily cleaned with water (picture 5).
To keep the heater in perfect condition, clean the filter once every six months REMEMBERING TO PUT IT BACK AGAIN
AFTERWARDS.
Every 250 working hours, the user is notified of the need to clean the filter on the back of the product. The warning is
given in the form of a running message on the display that reads
left part of the display:
Even when the display is showing the message indicated above, the product continues to work in the mode active at the
time the notification appears.
If any key is pushed when the notification is displayed, the built-in counter is reset and the notification will be displayed
again after another 250 working hours. Confirmation of resetting is given by a message on the display for 3sec that
"OK "
reads
.
If the filter is cleaned before reaching 250 working hours, the built-in counter can anyway be reset by pressing for 10sec
M
the
button. Confirmation of resetting is given by a message on the display for 3 seconds that reads
4. Command description and functioning
The following controls are available on the front panel (picture 6):
A -
Stand-by
B -
Increase
C -
Decrease
D -
Mode
E -
Display
An additional lamp located to the right of the control interface lights up when the product is running and emits hot air.
The product can be operated in 3 different modes: automatic, programmed or frost free.
Automatic Mode
In this mode the product works to reach and maintain the Comfort temperature set by the user. An automatic power manage-
ment system allows optimum control of consumption and precise adjustment of the comfort level automatically maintaining the
selected temperature constant over time, in accordance with what has been set on the electronic thermostat.
In automatic mode is also available a special feature, which is activated at user's choice, which allows to detect the possible
opening of a window and force the functioning to the Frost free mode to minimize energy waste.
" FILtEr "
. A warning icon will also be visible on the
26
"OK "
.