Télécharger Imprimer la page

Publicité

Liens rapides

USER MANUAL
IMPORTANT SAFETY PRECAUTIONS
CULTIVATION BEST PRACTICES
GENERAL CARE
SYSTEM HARDWARE & ACCESSORIES
ASSEMBLY INSTRUCTIONS
DIMENSIONS AND WEIGHT
CAUTIONS & WARNINGS
PRODUCT GUARANTEE & WARRANTY
4
4
4
5
6
9
10
16
1

Publicité

loading

Sommaire des Matières pour FLUENCE SPYDRFANG

  • Page 1 IMPORTANT SAFETY PRECAUTIONS CULTIVATION BEST PRACTICES GENERAL CARE SYSTEM HARDWARE & ACCESSORIES ASSEMBLY INSTRUCTIONS DIMENSIONS AND WEIGHT USER MANUAL CAUTIONS & WARNINGS PRODUCT GUARANTEE & WARRANTY...
  • Page 4 IMPORTANT SAFETY PRECAUTIONS GENERAL CARE • The system should only be cleaned as directed in the Fluence’s Fixture SPYDR Fang system is passively cooled with zero moving components Cleaning Recommendations which can be downloaded from the Fluence They are designed for accepted horticulture environments and years of Support Center www.fluence.science/support-center/.
  • Page 5 SYSTEM HARDWARE & ACCESSORIES SPYDR Fang Light Fixture Power Supply Dimmer Module Power Supply Brackets (2) Lance Hangers (2) AC Cable (Check for label on box for what is included) SR-2R47-I-LVG-DM-06-N5P-M-S-AR SR-2R47-I-LVG-DM-06-N6P-M-S-AR SR-2R47-I-LVG-DM-06-TFP-M-S-AR SR-2R47-I-LVG-DM-06-ASP-M-S-AR 240V PLUG 120V PLUG 6-15P 5-15P CEE 7/7 SAA/3...
  • Page 6 AC AND DC CABLE INSTALLATION WARNING: Risk of Electrical Shock Turn off and disconnect the power before installing, moving, or cleaning to reduce the possibility of serious injury DO NOT connect or disconnect cables to or from the power supply or LED light bar while energized Test all cable connections for correct and secure engagement after installation INSTALLATION OF THE DC POWER CABLE TO THE POWER SUPPLY AND LED LIGHT BAR All DC cables use a push-lock type M19 2-pin connector to connect the cable to the power supply and LED light bar.
  • Page 7 AC AND DC CABLE INSTALLATION INSTALLATION OF THE AC POWER CABLE TO THE POWER SUPPLY All AC power cables use a push-lock type M19 3-pin connector to connect the cable to the power supply. The connection to power is available in several plug types for receptacles, or in pigtails for direct wiring To Attach or Remove the Connectors: To install the connector, match up the keyed...
  • Page 8 ASSEMBLY INSTRUCTIONS Take caution when handling light bars. Ensure the LED array does not come in contact with sharp objects or force that may damage the diodes. Unbox and unfold the SPYDR Fang light fixture (A) and gently place it on your rack or a flush, stable surface Place the power supply unit (B) on a flat level surface and identify the reinforced corner mounts on unit and securing posts on brackets (D) Carefully insert bracket posts into the corner...
  • Page 9 ASSEMBLY INSTRUCTIONS Flip the power supply, center it on the fixture, and gently click the brackets onto the light bars Use the flanges of the bracket for this DO NOT push on the power supply directly to assemble brackets Plug the cable from the light fixture onto the power supply Identify two points on the structure that align with center hinges “CLICK”...
  • Page 10 ASSEMBLY INSTRUCTIONS Remove cap from dimming port on the power supply Line up the pins and push the dimmer on to the dimming port, and then twist the locking ring clockwise until hand-tight With the included AC power cable, first plug in to the power supply on the opposite port from the dimmer module then plug it in to your power source Use knob on dimmer to adjust your dimming preference from...
  • Page 11 DIMENSIONS AND WEIGHT FIXTURE WEIGHT: 16 7 lb [7,6 kg] POWER SUPPLY WEIGHT: 8 1 lb [3 7 kg] 43” (109 cm) 4” (10 cm) 47” (119 cm) 11 9...
  • Page 12 • DO NOT connect to live power until installation is complete and all connections are made • DO NOT modify or alter the product; doing so will void the warranty Please refer to the Fluence Terms and Conditions and Limited Warranty for further details •...
  • Page 13 CHEMICAL EXPOSURE PRECAUTION Fluence lighting systems are designed to be resilient against crop protection products Many chemicals used in the Commercial Horticultural Industry are corrosive to electronic equipment If the luminaire is accidentally exposed to a corrosive liquid or vapor (e g VOC –Volatile Organic Compound and H2S –...
  • Page 14 odbywać się zgodnie z obowiązującym prawem ceeding voltages above SELV. F Le produit protege doivent etre elimines conformement a la legislation nationale en vigueur. I Identificazione RAEE del dis- krajowym. SK Označenie zariadenia WEEE: des risques d’electrocution grace a la tres basse positivo: Non smaltire con i rifiuti domestici! Lo smal- Nelikvidujte v ramci komunalneho odpadu! Riadna tension de securite (TBTS) ;...
  • Page 15 provisions of the United Kingdom guidelines. mas Jungtinės Karalystės gairių nuostatas.Marka koji premašuju SELV. RO Produsul protejează europeiske retningslinjene. DK CE-m.rkning: Signify erkl.rer, at dette produkt overholder de grundl. Маркировка на UKCA: Signify декларира, че UKCA: Signify tiddikjara li dan il-prodott jikkonforma impotriva riscului de electrocutare cu tensiune de ggende krav og relevante bestemmelser i de europ.
  • Page 16 OUR PRODUCT GUARANTEE & WARRANTY Every SPYDR Fang system is engineered and built by Fluence Bioengineering using state-of-the-art robotics and hand craftsmanship. All SPYDR Fang systems are guaranteed against manufacturing defects for three years from date of purchase. Contact us at support@fluence-led.com for more warranty information.