INSTALLATION AND COMMISSIONING
DEVICE FIXATION
As you want, the device can be fixed to the wall or others
fixtures of the installation by means of the front fixations (1)
or the four threaded holes (2) placed
the device.
CONNECTION TO HYDRAULIC SYSTEM
This equipment is intended to be installed directly in the
distribution pipeline. The device has a 1/2" BSP connection
at both inlet and outlet.
Prior to installing the equipment, notice the location of the
inlet fluid connection indicated as "IN" (3). It is mandatory
to respect the flow direction for proper operation.
Avoid installing the device between rigid connections to
prevent efforts transmission of the pipeline. It is
recommended to install a pressure relief system on the line
to prevent damage from thermal expansion.
The device incorporates an easy access mesh-40 strainer
(4) to prevent damage from dirt or solid particles carried
by the fluid.