High Altitude Conversions
IMPORTANT: You must convert LP gas with LP gas high altitude
kit Part Number W10686630 or Natural gas with Natural gas high
altitude kit Part Number W10686629. If you need to convert LP
gas to Natural gas high altitude or Natural gas to LP gas high
altitude, you must convert the pressure regulator. For this, follow
steps 1 through 3 of the necessary conversion.
Natural Gas Orifice Spud Chart for High Altitude Conversion
See chart in the "Natural Gas High Altitude Conversion Kit."
Burner Locations
30" (76.2 cm) and 36" (91.4 cm) Models
A
E
A. Left rear burner
B. Center burner
C. Right rear burner
5. Remove all burner caps and burner bases. Be sure to keep
the cap and base for each burner together. This will assure
that the cap and base are reinstalled on the proper burner.
F
E
A. Gas tube opening
B. Burner cap
C. Burner base
6. To convert burners:
Insert 7.0 mm nut driver down onto the gas orifice
spud (C) and remove by turning it counterclockwise
and lifting out.
Set gas orifice spud aside.
Replace with correct Natural gas orifice spud. See the
Natural Gas Orifice Spud Chart.
B
C
D
D. Right front burner
E. Left front burner
A
B
C
D
D. Orifice holder
E. Igniter electrode
F. Burner base notch or hole
B
A
C
Standard and
simmer burners
A. Igniter electrode
B. Orifice holder
C. Orifice spud
IMPORTANT: Place LP gas orifice spuds in plastic parts bag
for future use and keep with package containing literature.
7. Replace burner bases and burner caps.
IMPORTANT: Be sure that the electrode aligns with the
notch or hole in the burner base. The igniter electrode is
ceramic and could break during installation of the burner
base.
A
A. Burner cap
B. Electrode
C. Burner base
8. Open shut-off valve in the gas supply line. The valve is open
when the handle is parallel to the gas pipe.
9. Once you have completed converting all of the cooktop
burners, test the cooktop for leaks by brushing on an
approved noncorrosive leak-detection solution. If bubbles
appear, a leak is indicated. Correct any leaks found.
10. Plug in cooktop or reconnect power.
11. Adjust valve according to the "Low Flame Height
Adjustment" section.
C
B
A
Dual flame burner
A. Igniter electrode
B. Orifice holder
C. Orifice spud
D. Orifice simmer
C
B
D
7