I N S TA L L AT I O N
R E P L AC I N G T H E M O D U L A R E M I T T E R
During replacement of the Modular Emitter, it is recommended to connect the
replacement Modular Emitter to the D3 power supply to prevent damage to the
Modular Emitter should it be accidentally dropped.
1.
Unlock the tilt lock by pulling it toward the fixture aperture. The tilt lock is
the red horizontal lever to the right or left side of the Light Engine.
Tilt the Light Engine to 40°.
2.
Unlock the rotation lock by pulling it toward the fixture aperture.
The rotation lock is the red vertical lever across from the Light Engine.
Rotate the Light Engine to allow access to the power supply.
3.
Remove power supply from docking station but leave wiring connected.
Place power supply inside D3 housing near aperture to provide easy access.
4.
Remove four T10 Torx screws from heatsink to release the old Modular
Emitter.