2.2.1.1 LG Chem batteries
Connect the battery cable eyelets: positive (+, red), negative (-, black) of the battery and the CAN communication
cable (included), as in Pic.6. It is also necessary to set the switches on the panel shown in Pic.7:
SW Select (1): Value: 0 0 1 1 (OFF OFF ON ON) (LGC Smart - Smart communication protocol).
Pic.6 - Power cable
2.2.1.2 Pylontech Batteries
Connect the quick clamps of the power cables supplied: positive (+, orange), negative (-, black) to the battery and
the CAN communication cable (included), as in Pic.9. Make sure that the quick clamps are correctly inserted into
the battery (you should hear a "click" once they are in the correct position).
4 - INVERTER CAN
CABLE
5 - POWER
SWITCH 1
6 - BUTTON
BATTERY START
5 - POWER
SWITCH 2
3 - SW ADDRESS
ALL OFF
Internal connection to the Pylontech accumulator bank:
1. Connect the parallel cables (ORANGE and BLACK) between the MASTER battery and SLAVE battery;
2. connect the battery communication LINK cable: MASTER battery on Port 1, SLAVE battery on Port 0;
3. set all ADDRESS configuration switches to the OFF position, as they are not used.
4. Connect the CAN-BUS cable for communication with WRM60 X.
WRM60 X
User manual
Pic.7 - SWITCH settings
Pic.9 - Cable installation on Pylontech battery
10
Pic.8 - CAN LG Chem communication cable
2 - LINK SLAVE
CABLE on Port 1
2 - LINK SLAVE
CABLE on Port 0
EN
1 - POSITIVE
1 - NEGATIVE