TECHNICAL DATA
Dynamic pressure min: 0.5 bar
MAX working pressure: 5 bar
Recommended working pressure: 1-5 bar
It is recommended to use a pressure reducer,
if there are static pressures higher than 5 bar inside the system.
MAX hot water temperature: 80°C
RULES FOR INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKS
In order for your appliance to function properly and to last over time, the installation and maintenance procedures
illustrated in this booklet must be followed. Rely on a qualified plumber. Make sure that the system has been
cleared of all existing debris and impurities.
INSTALLATION
Fig. 1-2: Overall dimensions of the sink.
Drill a Ø35mm (1.38 in) hole on the support surface.
Support surface thickness max 40mm (1.27 in).
Fig. 3: Insert the gasket into the sink body. Insert the sink body into the hole.
Fig. 4: Fix the sink body with the fixing kit supplied.
Fig. 5: Screw the threaded dowel located behind the body of the tap for fixing.
Fig. 6-7: Screw the hoses to the sink. Connect the hot water hose to the water supply system. Connect the
remaining hose to the "Raw water outlet" purification box.
Fig. 8: Insert the quick couplings for the Ø4 pipe into the carbonator fridge as shown in the figure.
Fig. 9: Check the correct position of the handle. Cut the Ø4 pipe to a suitable length, making sure the cut
is perpendicular to the pipe.
WARNING: Insert the pipes under the sink body into the appropriate fittings as shown in the figure.
Fig. 9a: Insert the tube into the "Cold out" under-sink refrigerator.
Fig. 9b: Insert the tube into the "Sparkle out" under-sink refrigerator.
Unscrew the pressure reducer to activate the sparkling water flow.
Fig. 9c: Insert the tube into the "Still out" under-sink refrigerator.
Fig. 10: Open the intermediate valve in the purification box.
Fig. 11: If the digital meter setting has not yet been carried out, follow the steps below.
DIGITAL LITER COUNTER SETTINGS:
The liter-counter is of the TIME-FLOW type, it measures the passage of water in liters or gallons.
Battery installation: slide the battery compartment cover and insert 2 AAA batteries. Close the lid.
Set the filter capacity: Press and hold the DISPLAY for 4-5 seconds. then press RESET and release both
buttons. The DigiFlow 8000T will enter the filter capacity registration procedure.
Now press DISPLAY to choose the filter capacity. The sequence is 100-200-300... .9800-19900-OFF
(Warning: set 15.000 L).
By holding down DISPLAY you can speed up the selection sequence. After choosing the correct capacity,
press RESET to save the setting.
Now press DISPLAY 2 times to enter day settings, leave OFF mode and press RESET.
Operations: The DigiFlow 8000T will turn on automatically when the water passes.
It will turn off automatically after 10 seconds if there is no water passage. Press DISPLAY to view the past
volume of water or press DISPLAY again to view the remaining capacity of the filter.
End of capacity alarm: when the filter reaches capacity 0, the Digiflow will produce an audible alarm to alert
the user to change the cartridges.
Press RESET to turn off the alarm and restore the filter capacity.
Low Battery Alarm: When the power of the batteries is lower than the normal working level a buzzer will
emit two beeps to warn you to change the batteries. The information will be kept in memory in case the
battery is completely discharged or removed.
Reset: Press and hold RESET for 8 seconds to reset the liter counter.
Fig. 12: Screw the handwheels on the purification box casing and check the closure of the purification box.
Fig. 13: Open the main valve of the CO2 bottle by turning clockwise until it stops, without forcing it.
ATTENTION: Dispense cold, sparkling and still water to check the correct position of the connection pipes.
If the water outlet does not correspond to what is specified on the diverter handle, remove and rotate the
handle correctly until correct dispensing is achieved.