L2 remains lit, indicates that the device is operating correctly;
L2 flashing, indicates that the memory module is not present or there is a system error.
L3-L4 are numbered from 1 to 8 and indicate the status of the corresponding photoelectric cells.
L3 red safety Led continuously lit, photoelectric cells are at rest;
L3 red safety Led flashing, photoelectric cells are in alarm;
L4 green status Led continuously lit, memorised photoelectric cells with full battery charge;
L4 green status Led flashing slowly, memorised photoelectric cells with low battery charge;
L4 green status Led flashing quickly, memorised photoelectric cells with a battery to be replaced as soon
as possible (In this case the buzzer will sound 5 rapid beeps every 20 seconds).
L3 - L4 off, memorised photoelectric cells have not been memorised.
ATTENTION! If safety devices are stored with firmware that is not compatible with the mode set, leds L3 - L4
corresponding to the incompatible safety devices will start flashing on the interface and the system will be
blocked. In this case, set mode 4 to cancel the incompatible safety devices.
Dip-switch and jumper settings on the memorised photocells DIP S1, fig. 6.
Using the dips on the photoelectric cells you can choose the output on the stationary unit to which the safety
device is to be associated. Set this status before memorising the safety device itself
If you wish to change the output pairing of a security device that has already been memorised:
1. set the dip on the receiver to the desired position;
2. cancel and memorise the security device again.
The new setting will overwrite the previous setting.
ON
OUT1
18
ON
ON
1 2
1 2
OUT2
1 2
OUT3