If external control is connected: Push the confirmation
button <
> for 3 sec. The thermostat will now be in
Manual mode. Push again the confirmation button <
>
for 3 sec. The thermostat will go in "booster" mode and the
current set temperature will increase by 5°C for
2 hours. This increased temperature is shown on the
display. Automatic reverts to the set temperature after
2 hours or if the confirmation button <
> is pushed
again for 3 sec. within the 2 hour period.
4.2.2 External set back
To utilise the set-back function and reduce the current set
point by 3.5°C: Connect a closing contact between the FP
terminal and phase terminal e.g. a closing timer switch.
When the contact is closed, the symbol "P" is displayed in
the upper left corner indicating activation.
To enable manual control mode: Push the confirmation
button in 3 sec. Normal set temperature control is active.
Push again the confirmation button <
> in 3 sec. for
leaving the Manual mode to Booster mode. Push the
confirmation button
<
> again 3 sec to go the AUTO mode.
4.2.3 Lock
Lock and unlock the thermostat
It is possible to lock all the settings for the thermostat. (eg
public buildings)
Lock: Push simultaneously <
> and <
> and <
>
The key symbol is displayed when the thermostat is locked.
Unlock: Push simultaneously <
> and <
> and <
>
4.2.4 Summer Mode (Heating Off)
Normal Menu:
In both case (floor or room sensing mode) the temperature
seen on the thermostat correspond to the room temperature.
In room sensing mode, the user sees the temperature
measured by the thermostat (Room Temperature)