35.1 Introduction - Installation
WARNING:
safety chapter before you install the product.
CAUTION:
Use original spare parts and
installation material.
Note:
Refer to www.husqvarna.com for more
information about installation.
35.2 To examine where to put the
reference station
CAUTION:
If there is a lightning rod in
the area, do not install the reference station
higher than the lightning rod.
CAUTION:
Do not install the reference
station on a flagpole. Movements of the
reference station will affect the correction
data sent to the product with the accurate
position.
Install the reference station on a fixed object that
cannot move or rotate.
Install the reference station on a post or a wall. The
post must be 32-55 mm / 1.26-2.16 in. in diameter
to fit the attachments on the reference station.
Note:
If the reference station is installed on a
wall the top of the reference station must be above
the wall. There must be no metal in the wall.
Make sure that the reference station has full view
of the sky. Make sure that the sky is visible without
obscuration in all directions above 10° elevation
angle.
1512 - 005 -
35 Installation
Read and understand the
160°
10°
Install the reference station at a high position for
increased radio signal range. Install the reference
station at minimum 2.5 m / 8 ft. height.
Make sure that the maximum distance between
the reference station and the product is 500 m /
1640 ft. when free line of view. Objects between
the reference station and product decreases the
distance.
Install the reference station where the radio signal
reaches all parts of the work area. Large objects
can block the radio signals.
Make sure to have a free line of sight between
the product and the reference station for optimal
correction data.
Note:
Special settings are necessary if the site has
more than one reference station. Speak to your local
Husqvarna representative for more information.
35.3 To examine where to put the
power supply
WARNING:
cable. There is a risk of electrical shock.
CAUTION:
Make sure that the blades
on the robotic lawn mower do not cut the
power cables.
Put the power supply in an area with a roof and
protection from the sun and rain.
Put the power supply in an area with good airflow.
Use a residual-current device (RCD) when you
connect the power supply to the power outlet.
Extend the low-voltage cable if necessary. The
low-voltage cable can be extended up to 100 m /
328 ft.
10°
Do not cut the low-voltage
Installation - 53