TROUBLESHOOTING GUIDE
Trouble
Unit does not operate on any
speed setting
Motor does not turn on.
Not enough humidity.
Too much humidity.
(condensation becomes heavy
on cold surfaces in room)
Water leak
Odor
Probable Cause
No power to unit.
Unit has run out of water and
turned off automatically.
Refill switch operation/improper
positioning of float assy.
Check motor/fan operation.
Wick may be installed
incorrectly
Wick is old and ineffective.
Humidistat is not set high
enough
Humidistat is set too high.
Cabinet may have been overfilled.
There is a safety overflow hole in
rear of cabinet.
Bacteria may be present.
9
Remedy
Ensure polarized plug is fully inserted in
wall outlet.
Refill reservoir.
Ensure float assembly is correctly
positioned as described in
"Water FIll", page 5.
CAUTION: Do not touch the fan
when accomplishing this test, as
the motor may turn on.
To test the motor, turn unit ON and
turn all knobs fully ON.
Turn the chassis over and insert finger
into tab where float rod is supposed to
go. If fan turns on, the fan and motor
are working correctly.
Remove and reinstall wick correctly.
Replace wick when clogged or
hardened with minerals.
Increase humidity setting on control
panel.
Reduce humidistat setting or increase
room temperature.
DO NOT OVERFILL cabinet. Correct
water level is indicated inside of
cabinet side wall.
Clean and disinfect cabinet following
Care and Maintenance instructions.
Add EPA registered Bacteria Treatment
according to instructions on the bottle.
It may be necessary to replace the wick
if odor persists.