MODEL Nº: 62981
:
N
U
Angle Accuracy *1
Display range
Resolution
Target memory
Target range
Data memory size
PC Connectivity *2
Button
Battery *3
Operating Temperature
Storage Temperature
Humidity
Drop Test
Environmental test *5
Electromagnetic
compatibility test *6
Note:
*1: The accuracy of the readout is guaranteed from 0.0° to 360.0° and the test speed is 30°/sec.
For maintaining accuracy, calibrate the meter at regular intervals (1 year recommended).
*2: Use a special designed cable (accessory) to upload record data to PC.
*3: Two AAA batteries (Toshiba carbon-zinc R03UG battery)
*4: Horizontal and vertical test
*5: Environmental test:
a. Dry heat
SELECTION GUIDE
Communication
SPECIFICATIONS
LED
No
USB
±2° for 90° rotation
@ 30°/sec
0~999.0°
0.1°
9 sets
1~360.0° (increment 1°)
BN
50
No
6
(1 Red + 5 Green)
5
AAAx2
-10ºC~60ºC
-20ºC~70ºC
Up to 90% non-condensing
1 m
Pass
Pass
BU
250
Yes
15

Publicité