Model
≤ 3,5 kW
> 3,5 kW
NOTE!
The supply voltage should be consistent with the rated voltage
of the air conditioner.
Connect the cable to the outdoor unit
1.
4.5 Meter cable for electrical connection between indoor and outdoor unit is delivered with the pac-
kage and is included in the refrigerant piping sleeve.
2.
The electrical cable is provided with an electrical quick connector.
3.
The outdoor unit is also provided with electrical quick connector.
4.
Remove the control cover from the outdoor unit by loosening the screw.
5.
Hold the indoor plug connector and insert the mating plug connector located on the outdoor unit until
it fixed with a clicking sound. Secure the cable onto the control board with the cord clamp.
6.
Connect the grounding wire to the terminal on the control board individually.
7.
The electrical connection is finished now.
Outdoor unit
Control cover
Screw
Fig. 23
4
78
Input Rated Current
Power supply
(Switch/Fuse)
230V~50Hz
230V~50Hz
Outdoor unit
L
N
S
Plug connector
or
To indoor unit
Power cord size
16A
2,5 mm
16A slow
2,5 mm
L
N
S
'click'
Secure the cable with cord clamp
2
2