MULTI POSITIONS MODELS - SERIES 098
RATING AND PERFORMANCE
Firing rate (USGPH)*
Input (BTU/h)*
Maximum Heating capacity, (BTU/h)*
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire pressure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c.)
Overfire pressure with direct vent (inch of w.c.)
BECKETT BURNER; MODEL NX (Chimney or DV)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)
Minimum and Maximum pump pressure (PSIG)*
Head/Air setting
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER; MODEL 40-F3 (Chimney)
Burner tube insertion length (inches)
Nozzle (Delavan)
Minimum and Maximum pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER; MODEL 40-BF3 (Direct vent DV)
Burner tube insertion length (inches)
Nozzle (Delavan)
Minimum and Maximum pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
ELECTRICAL SYSTEM
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps)
Max. fuse size (Amps)
Control transformer (VA)
External control power available
Heating (VA)
Cooling (VA)
BLOWER DATA
Heating blower speed at 0.25" W.C. SP
Heating blower speed at 0.50" W.C. SP
Motor (HP) / number of speeds
Blower size (diam. x width)
GENERAL INFORMATION
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x depth)
Filter size (depth x hieght x thickness)
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons) at 0.5 SP
* INPUT & OUTPUT ADJUSTMENT
Pump pressure can be adjusted to maintain proper firing rate.
Increase pump pressure if flue gases temperature is under 400˚F
Adjust the total flue gas temperature between 400˚F and 575˚F (330˚F and 505˚F net approximately)
Adjust fan speed for air temperature rise of 55˚ to 85˚F.
** AFUE value established after minimum 20 hours of operation.
All manuals and user guides at all-guides.com
Table 6: Technical specifications
UNITS WITH 1/3 HP PSC MOTOR
0,50
70 000
59 200
55 - 85 Degr. F
-0.06 to -0.025
-0.035 to +0.010
+0.05 to +0.20
+0.03 to +0.15
NX56LQ
6 - Slot LQ head
0.40 - 60A
0.50 60A
155
0,5
85.0 ‡
85.0 ‡
F3 WITH AIR INLET DAMPER
0.40 - 70A
0.50 - 70A
155
0 / 1.5
85.0 ‡
85.0 ‡
0.40 - 70A
0.50 - 70A
155
0 / 3.25
85.0 ‡
85.0 ‡
115 - 60 - 1
MED-LOW
MED-HIGH
MED-LOW
MED-HIGH
1/3 HP / 4 speeds
10'' x 8''
16.875'' x 20 1/8'' x 40 3/4''
16'' x 19''
19'' x 19''
20'' x 20''
125 / 57
15
UNITS WITH 1/2 HP ECM MOTOR
0,60
0,70
0,50
84 000
98 000
70 000
70 400
80 800
59 200
1 3/4''
0.60 - 60A
0.40 - 60A
145
135
155
1,5
2,5
0,5
84,2
81,9
85.0 ‡
85.0 ‡
83,9
81,9
F3 WITH AIR INLET DAMPER
2 3/4''
0.60 - 70A
0.40 - 70A
145
135
155
0 / 2.5
1 / 3.5
0 / 1.5
84,2
81,9
85.0 ‡
85.0 ‡
83,9
81,9
BF3
2 3/4''
0.60 - 70A
0.40 - 70A
145
135
155
0 / 4
1 / 5.25
0 / 3.25
84,2
81,9
85.0 ‡
85.0 ‡
83,9
81,9
12.2
13.7
15
40
40
30
HIGH
See the ECM air flow table
HIGH
16.875'' x 20 1/8'' x 40 3/4''
2,5
0,60
0.70
84 000
98 000
70 400
80 800
55 - 85 Degr. F
-0.06 to -0.025
-0.035 to +0.010
+0.05 to +0.20
+0.03 to +0.15
NX56LQ
1 3/4''
6 - Slot LQ head
0.50 - 60A
0.60 - 60A
145
135
1,5
2,5
84,2
81,9
83,9
81,9
2 3/4''
0.50 - 70A
0.60 - 70A
145
135
0 / 2.5
1 / 3.5
84,2
81,9
83,9
81,9
BF3
2 3/4''
0.50 - 70A
0.60 - 70A
145
135
0 / 4
1 / 5.25
84,2
81,9
83,9
81,9
115 - 60 - 1
10.3
12.2
15
40
40
30
1/2 HP / ECM
10'' x 8''
16'' x 19''
19'' x 19''
20'' x 20''
125 / 57
3.0
‡ =

Publicité

loading

Ce manuel est également adapté pour:

Ovm098