Télécharger Imprimer la page

Mega MQ 250 Manuel D'instructions page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
Take the pump out of service when
the residual water level is reached by
pulling out the mains plug.
The float switch must be operated
manually to pump to the residual
water level:
1. Remove the mains plug from the
plug socket.
2. Lay the float switch up and fix it in
position.
3. Insert the mains plug into the plug
socket. The pump switches on and
starts to feed.
If the water drops below the residual
water level, (under 10/40 mm), the
pump will draw air in. In this case, the
pump must be vented when the water
level rises and before using it again.
XMAINTENANCE AND CARE
Cleaning the pump
After conveying chlorine-containing
swimming pool water or fluids that
leave a residue, the pump must be
flushed out with clear water.
1. Clean the suction slots on the
suction foot if necessary with clear
water.
STORAGE
In the event of a risk of frost, the
system must be drained completely.
DISPOSAL
Do not dispose of worn-out machines
or spent batteries (including
rechargeable batteries) in domestic
waste!
The packaging, machine and
accessories are made from
recyclable materials and must be
disposed of accordingly.
GB 04

Publicité

loading