Gas Supply Pressure
To avoid property damage, maximum gas supply pressure must not
exceed 14" WCP.
Appliance and individual shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test
pressures in excess of ½ psig (3.5kPa)(14" WCP).
Appliance must be isolated from gas supply piping system by closing
manual shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than ½ psig (3.5kPa) (14"
WCP).
Gas supply pressure for checking regulator setting must be at least 1"
WCP above manifold pressure shown on rating label.
Must use pressure regulator supplied with cooktop.
Gas Connection
Connect gas supply to regulator using hard pipe or a flexible connector.
Pressure regulator supplied with this appliance has a ½ " NPT female
connection.
A manual shutoff, not supplied with cooktop, must be installed in an
accessible location outside of cooktop.
Use joint compound that is resistant to action of propane gas on all male
pipe threads.
Use supplied pressure regulator only.
Do not overtighten gas fitting when attaching to pressure regulator.
Overtightening may crack regulator.
Support pressure regulator with wrench when installing gas fitting.
F
A—Union
B—Manual Shut Off Valve
C—Reducing Elbow (3/4-inch to 1/2-inch)
D—3/4-inch Stub
E—1/2-inch Nipple
F—Regulator
Hardpipe Connection
All manuals and user guides at all-guides.com
!
CAUTION
A
B
C
E
D
A—Regulator
B—Adaptor
C—Flexible Connector
D—Manual Shut Off Valve
Flexible Connection
9
Installation
!
WARNING
To avoid property damage or
personal injury, only use a new
flexible connector that is AGA/
CGA design certified.
• Do not use an old connector.
• Do not reuse a connector after
moving appliance.
A
B
C
D