OPERATION
AC current measurements
1 Set the Function switch to the ACA range.
2 Press the jaw trigger and clamp around, fully enclosing a single conductor. Do not allow a gap
between the two halves of the jaw. Refer to the diagram at right for the correct way to enclose
a single conductor.
3 Read the ACA value on the LCD.
DC current measurements
1 Set the Function switch to the DCA range.
2 Press the ZERO key to null the meter
display.
3 Press the Trigger to open the current
sense Jaw.
4 Fully enclose the conductor to be measu-
red. Do not allow a gap between the two
halves of the jaw.
5 Read the DCA value on the LCD.