Télécharger Imprimer la page

Beta 1760PA/80 Mode D'emploi page 17

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
Low Battery indication
Auto OFF
Operating conditions
Storage conditions
Altitude
Weight
Dimensions
Jaw opening
Standards
range specifications
Function
DC Current
AC Current (50/60Hz)
Non-Contact AC Voltage
Beta 1760 PA_80 Manuale.indd 14
All manuals and user guides at all-guides.com
"BATT" displayed on the LCD
approx. 7 minutes
32ºF to 86ºF (0ºC to 30ºC) 90%RH; 86ºF to 104ºF (30ºC to 40ºC)
75%RH; 104ºF to 122ºF (40ºC to 50ºC) 45%RH
- 14ºF to 140ºF (-30ºC to 60ºC); < 90% Relative Humidity
Operate at less than 3000 meters
6.2 oz. (175g) including battery
164 x 65 x 32mm (6.5 x 2.6 x 1.3") (HXWXD)
18mm (0.7")
EN61010-1, EN61010-2-032 Category II 600V, Category III 300V
Range
2A
80A
2A
80A
100VAC to 600VAC 50/60Hz
Resolution
Accuracy (of reading)
1mA
±(2.8% + 10 digits)
100mA
±(3.0% + 8 digits)
1mA
±(3.0% + 10 digits)
100mA
±(3.0% + 8 digits)
14
19/05/14 14:51

Publicité

loading