CS.VTR.IST-1 / Rev 1.2
Technical Specifications FINN / TJALLMO
Nominal heat input
Reduced thermal capacity
Nominal thermal output
Reduced thermal power
Efficiency at thermal nominal power
Efficiency at reduced thermal power
CO at 13% oxygen at nominal thermal power
CO at 13% oxygen at reduced thermal power
Maximum power uptake
Power uptake when running
Nominal voltage
Nominal frequency
Flue outlet diameter
Air intake pipe diameter
Minimum chimney draught at nominal thermal power
Minimum chimney draught at reduced thermal power
Combustion gas mass at nominal thermal power
Combustion gas mass at reduced thermal power
Ventilated pellet tank capacity (ducted)
Average exhaust flue gas temperature at nominal thermal power
Average exhaust flue gas temperature at reduced thermal power
Minimum safety distance from flammable materials
(side/rear/front)
* Power consumption only during the ignition cycle.
The appliance's heat output may vary depending on the type of pellets used.
Dimensions and connections data sheet FINN / TJALLMO
All the data sheets of dimensions and connections are visible by scanning the following QR Code from your smartphone:
4
https://docs.nordicfire.nl/it/guide/help/cs-
fna-tds-1
4
FINN
kW
7,0
kcal/h
6.020
kW
3,78
kcal/h
3.250
kW
6,4
kcal/h
5.500
kW
3,46
kcal/h
2.975
%
91,4
%
91,5
%
0,0081
%
0,0468
Watt
400
Watt
80
V
230
Hz
50
mm
80
mm
33
Pa
9,5
Pa
8,7
g/s
4,2
g/s
3,1
kg
14 (10)
°C
144,7
°C
115,4
mm
200 / 200 / 800
5
https://docs.nordicfire.nl/it/guide/help/cs-
tjm-tds-1
5
ENGLISH
5
TJALLMO
7,9
6.794
4,1
3.526
7,2
6.192
3,8
3.268
91,7
92,9
0,012
0,052
340*
32
230
50
80
50
9,0
9,7
5,3
3,8
-
131,7
93,2
200 / 200 / 800