GB
Fold out pages:
Type approvals
The system may only be operated in the following countries:
Germany, France, Belgium, Spain, Italy, Netherlands,
Denmark, Norway, Switzerland, Austria and Portugal.
Safety notes
• Installation is only possible in frost-free rooms.
• The control electronics are only suitable for indoor use.
• In the case of damage to the external transformer and
control unit connection cable, this must be replaced by the
manufacturer or his customer service department or an
equally qualified person, in order to prevent a hazard.
• When cleaning the fitting (the urinal) it must be ensured that
the tile frame behind which the electronics are installed is
not sprayed directly with water.
• In order to provide optimum water protection, the tile frame
must be sealed.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.
Applications
Element suitable for:
• direct connection to cold water supply
Technical Data
• Minimum flow pressure:
• Operating pressure:
• Recommended flow pressure:
• Test pressure:
• Temperature:
• Pipe:
• Connection thread:
• Integrated isolating valve
3
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk
All manuals and user guides at all-guides.com
Approval and conformity
0682
!
; 0700 !
This product conforms to the requirements of the relevant
EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
New installations
During installation, please note
• The distance between the control unit and the sensor must
not exceed 50m.
• The control unit must be easy to access for maintenance
work.
• During electrical installation outside the element, route the
supply line with a loop from below to the bowl inlet,
see fold-out page II, Fig. [1]. Attention should be paid to
rises in the last section.
• During installation inside a stud partition:
at least 50 x 50 x 0.6mm CW profiles, see Fig. [2].
• During installation in front of a stud partition:
- Use 75 x 40 x 2.0mm UA profiles, see Fig. [2].
- It is recommendable to fasten element (A) to a waterproof
plywood board (B).
Installation in front of wall
1. Prepare the wall for the installation, refer to the dimensional
drawing on fold-out page I.
2. Mark additional fixing holes, see fold-out page II, Figs. [3]
and [4].
3. Align element (A) horizontally and adapt the feet of the
0.5 bar
element (C) to the height of the floor structure, see Fig. [4].
max. 5 bar
4. Drill fixing holes and insert the wall plugs provided,
1 - 5 bar
see Fig. [5].
16 bar
5. Fasten the feet of the element (C) with the screws
max. 40 °C
and washers provided, see Fig. [6].
DN 15
6. Attach wall bracket (E) (special accessory) to the wall.
G ½
7. Align element (A) perpendicularly and fasten with screws,
see Fig. [7].