Télécharger Imprimer la page

CAME 001SDTEWL Mode D'emploi page 9

Publicité

Les langues disponibles

Les langues disponibles

English
DESCRIPTION
001SDTEWL is a double technology (passive infrared and microwave)
radio-based outdoor sensor.
The alarm is generated when both technologies detect together.
The sensor is tamperproof protected thanks to its built-in anti removal
system.
Precautions
WARNING. The device runs on lithium batteries. Handle with care.
Danger of explosion or fire. Do not throw the batteries into a fire,
do not heat or damage the batteries. Respect the shown polarities.
To replace the batteries contact a SKILLED TECHNICIAN.
Dispose of exhausted batteries in compliance with the laws in
effect, even when decomissioning the device. If any liquid comes
out, protect your hands with special gloves.
This sensor is designed to operate in very bright settings. The sensor,
however, must not be exposed to direct beams of very high intensity light.
We suggest installing the sensor in areas protected from weather
agents.
To maintain the protection level, you must use o-rings and issued
screws when installing.
Otherwise the product could malfunction, and the manufacturer
declines any liability in this case. The sensor can detect animal presence.
Technical data
Type
Power supply from 2 3 [V]
batteries
Draw when standing by [uA]
Draw while in alarm state [mA]
Estimated effectiveness [years]*
DUAL-BAND radio communication frequency
[MHz]
Microwave operating frequency [GHz]
Maximum range at 25°C [m]**
9 - 119RW89 ver. 1 05/2014
All manuals and user guides at all-guides.com
Minimum range at 25°C [m]**
Operating temperature [°C]
Relative humidity [%]
Weight [g]
Dimensions [mm]
Protection rating [IP]
Impact resistance [IK]
* The estimated effectiveness of the sensor's battery in inversely propor-
tionall to the number of detections it is subjected to (regardless of whether
the alarm system is armed or not). If the sensor is installed in areas with
high-flow rates, then the battery life could be drastically shortened.
** The maximum range greatly depends on the outside temperature.
Features A
LED
LED
Color
Red
 DL1
Red
 DL2
Blue
 DL3
Red
 DL4
Green
 DL5
Dipswitch 
001SDTEWL
CR123A
40
DIP1 (supervision)
< 80
ON
2
Enabled
1
868.65/433.92
Disabled
OFF
1
24
18
For the system to work properly the supervision MUST be ENABLED
3
(DIP1=ON)
-40 ÷ 70
DIP2 (radio test)
95
ON
460
190x85x75
54
OFF
10
DIP3 (mode)
ON
OFF
Move DIP3 only when no detection is taking place (if the LEDs are ena-
bled, move the DIP when they are all turned off). The sensor confirms
the passing to TEST or NORMAL mode by giving off sounds:
- TEST -> NORMAL: some quick "beeps"
Meaning
- NORMAL -> TEST: long "beep"
IR detection
If you hear no sound, this means that the sensor did NOT go into chosen
Micro wave detection
mode: Just repeat the moving of DIP3
Alarm
DIP4 (LED and BUZZER adjustments)
Learning
Learning
OFF
ON
DEFAULT
DIP5-DIP6 walk test
The walk tests are for making detection area adjustments to the sensor.
Infrared and microwave adjustments are independent.
Enabled. The sensor transmits a radio signal at one second
intervals to test the radio range
Disabled. Use this mode with NORMAL operation
TEST
NORMAL
Buzzer, DL1, DL2 disabled.
The DL3 is managed by jumper JP3. Use this working
mode in normal operation to increase the batteries' life.
Buzzer, DL1, DL enabled
OFF Normal operation
ON
IR walk test (DL1 stays on, DL3 notifies of detection)
OFF
ON
MW walk test (DL2 stays on, DL3 notifies detection)
OFF

Publicité