ENGLISH
DESCRIPTION
001SIRCWWL is a curtain-effect wireless volumetric
sensor for indoor and outdoor protected environments.
Two more wired devices, like shutter contacts or other
sensors can be connected to wirelessly transmit
alarms. The two auxiliary inputs on the terminal block
can be configured independently, to manage normally
closed inputs or pulse counters, like magnetic contacts
on frames and rope contacts for shutters.
The sensor is also equipped with an anti-opening de-
vice and a tear-resistant device.
If the container is opened or torn from the mounting
surface, the sensor triggers the alarm.
Precautions
CAUTION. The device works with lithium batteries.
Handle with care.
Risk of explosion and fire. Do not throw batteries
into fire. Do not weld or damage the batteries.
Make sure the polarity is correct.
Have the batteries replaced by a SPECIALISED
TECHNICIAN. Dispose of used batteries according
to applicable regulations, even if the device will no
longer be used. If any liquid leaks outwear protect-
ive gloves.
Technical data and features
Type
001SIRCWWL
Powered by 1 x 3 [V] lithium
CR123A
battery
Frequency [MHz]
433.92/868.65
7 - FA00049M4A ver. 1 08/2015
All manuals and user guides at all-guides.com
Max current draw [mA]
Absorption in standby [uA]
Detection range [m]
Coverage of the 2 beams
Range
Operating temperature [°C]
Dimensions [mm]
Protection rating [IP]
Weight [g]
Minimum control unit FW ver-
sion
SW LINK version
EN50131-1, EN50131-2-2 Grade 2,
EN50131-5-3, EN50131-6: Type C, EN50130-5
Environmental Class III
Description B
a Battery;
PIR sensor;
Button for self-learning;
Anti-opening tamper;
SW1 dip switch;
Input terminal board;
SW2 dip switch;
Indicator LED;
25
Tear-resistant tamper;
25
LED indicator
5
Colour
Lens 79° thickness
Red
7.5°
Green
200 m with no ob-
stacles (@868.65
Red+Green
MHz)
100 m with no ob-
Programming
stacles (@433.92
Insert the battery in the battery holder. After powering
MHz)
the sensor, the red LED and the green LED will light
-20 / +50 °
up alternately for about ten seconds until the end of
152x30x38
initialisation.
43
Proceed with the settings, selections and tests on the
90
dip switch.
2.2.0 b1
SW1
2.1.3 b11
Dip 1 OFF = input I1 - NC
Dip 2 OFF = input I2 - NC
OFF = after detection,
Dip 3
it is deactivated for
three minutes
Dip 4 ON = LED enabled
Meaning
Alarm
Alarm reset (input or tamper)
Crossing permitted (see SW2 DIP2
function)
default configuration
ON = input I1 - pul-
se counter (5x10"),
for vibration or rope
contacts
ON = input I2 - pul-
se counter (5x10"),
for vibration or rope
contacts
ON
=
continuous
transmission at each
detection (Walk Test)
OFF = LED disabled